YOSHIDA X-eraSmart changes the rules in the Panoramic segment with its unique sensor technology, superior image quality and ease of use.
It obtains sharp and high-resolution images by creating the finest details of more than 4500 high-resolution images. (16 bit, 65536 grading)
Multi-Focus Layer technology allows for optimal focus
The unique panoramic image acquisition technology (Image Creator) selects the most appropriate focus layer once imaging is complete. After imaging, it is possible to refocus on a point to ensure a clear image.
While the direct CMOS sensor creates high-quality images, it also allows the patient dose to be reduced by 50%. It also reduces the radiation time (compared to conventional sensors) and achieves the lowest patient dose.
At the same time, since it does not require re-takes, it prevents loss of time and radiation exposure even if the patient moves or is positioned incorrectly.
*Child mode ensures the safety of child patients.
New generation Premium HD
• Premium High Definition (14 sec) - Standard Panoramic
Thanks to the direct CMOS sensor, the unique panoramic image algorithm enables direct conversion of X-rays into electronic signals, creating super high-resolution and noise-free images.
• High Speed Shooting Mode
Even the 8-second capture mode provides high-quality images for accurate diagnosis. Thanks to the direct CMOS sensor, the unique panoramic image algorithm enables direct conversion of X-rays into electronic signals, creating super high-resolution and noise-free images.
• Super High Resolution Clinical Image Quality for Accurate Diagnosis
Using a direct CMOS sensor and unique image acquisition technology, it provides sharp images free from blur.
• Direct CMOS Sensor
Instead of indirect band gap silicon used in other devices, a direct gap Cadmium Telluride (CdTe) sensor is used. Thanks to the feature of the semiconductor, X-rays are directly converted into electronic signals and the sharpest image is obtained.
• Conventional Sensor
In conventional sensors, X-rays are converted into visible light by a scintillator and the CCD element converts the light into an electronic signal. During this process, the scintillator electrons scatter, which causes the image to become blurry.
• Image Creator
The focal point position and shape can be adjusted to optimally focus the unclear point. The Active Tomography feature provides the opportunity to recreate the image even after shooting, according to the patient's anatomical shape and size.
• Easy Transition to Cephalometry
With its compact dimensions and the same easy-to-use features, the cephalometric arm can be added in the clinic when necessary. To perform cephalometric shooting, it is sufficient to move the sensor from its panoramic position to its cephalometric position.
* A sensor suitable for cephalometric imaging is required.
• 3 Point Head Support
The patient's head is supported from 3 points to keep it stable during shooting.
• Easy Positioning
3 positioning beams ensure optimal patient positioning.
• 800 mm Elevation Range
The chin support is adjustable within a height range of 800 mm; Thus, it can adapt to all children, adults and patients in wheelchairs.
• Space Efficiency and Compact Design
The assistant position may be on the right or left, depending on availability and the structure of the room. This provides efficient use of limited space in the X-ray room.
Some Sample Images Taken from Clinics: